SKW
SKB
PRAKAB
ICS
KONEKA
IKK

Menu

Certificate

EcoVadis Rated: Bronze Medal

Join SCHWECHATER KABELWERKE GMBH on its sustainability journey! Our EcoVadis assessment has earned us a Bronze Medal, an award given to the top 35% of companies evaluated worldwide.

Certificate
  • Drum return
  • DOP Finder
  • Download Center
  • Compliance
  • Whistleblowing
  • Videos
  • Stock Level
SKW logo
Cu
SKW
Date: 05.12.2025
Cu
Quotation€ / 100 kg:1,043.92
Surcharge€ / 100 kg:913.92
SKB-Group
Date: 05.12.2025
Cu
Quotation
€ / 100 kg:1,031.57

All statements without guarantee.

Al
SKW
Date: 05.12.2025
Al
Quotation€ / 100 kg:408.03
Surcharge€ / 100 kg:308.03
SKB-Group
Date: 05.12.2025
Al
Quotation
€ / 100 kg:360.92

All statements without guarantee.

Cables

E-YCY

Download PDF

Add to inquiry

Download PDF

To inquiry

PVC/PVC copper energy cables, screened

Copper 0,6/1 kV, screened or armoured

Power distribution and control cables in power stations, industrial installations and switchgears, as well as in local mains. For fixed installation underground, in interior premises, cable ducts, in the open air and in water – as permitted by the local building regulations – if protection against shock hazard in the event of mechanical damage or electrical screening is required.

Design

This product consists of:

  • 1
    Copper conductor, round solid (RE) resp. round stranded (RM)
  • 2
    Core insulation (PVC)
  • 3
    Inner covering (EPDM)
  • 4
    Concentric screen (bare copper wires) and counter helix (copper tape) and optional plastic tape
  • 5
    Sheath (PVC black, UV-resistant)

Technical Data

Standard: 
  • ÖVE/ONORM E 8200-603 (HD 603)
  • ÖVE/ONORM E 8200-627 (HD 627)
Certificate: ÖVE Austria
Test Voltage: core/core 4 kV / 50 Hz
Rated Voltage: 0.6/1 kV
Bending radius (min.): 
  • 12 x Ø of cable (multicore)
  • 15 x Ø of cable (singlecore)
Fire properties: 
  • EN 60332-1-2: self-extinguishing
  • CPR: Eca
Core identification: HD 308 S2
Temperature range: 
  • Laying temperature: min. -5°C
  • Operating temperature: -50°C up to 70°C
  • Conductor temperature: max. 70°C
  • Short circuit temperature: max. 160°C
Cable image - E-YCY
+
-
Cable image - E-YCY
+
-
Cable image - E-YCY
+
-

Contact us

Are you interested in this product?

Dogan Özcan

Product supervisor

+43 (0) 1 70170-154
[email protected]

Options

Add to inquiry
Number of cores x nominal cross-section / cross-section of screen (mm²)
Number of cores x nominal cross-section / cross-section of screen (mm²)
Max. conductor resistance (Ω/km)
Current rating in the earth (A)
Current rating in the air (A)
Outer diameter appr. (mm)
Total weight appr. (kg/km)
2 x 2 RE / 2
12.1
32
20
13.5
238
2 x 2 RE / 16
12.1
32
20
14.2
316
3 x 2 RE / 2
12.1
27
20
13.9
261
3 x 2 RE / 6
12.1
27
20
14.5
309
3 x 2 RE / 16
12.1
27
20
14.9
331
4 x 2 RE / 2
12.1
27
20
14.6
293
4 x 2 RE / 16
12.1
27
20
15.6
427
5 x 2 RE / 2
12.1
19
14
15.5
327
5 x 2 RE / 16
12.1
19
14
16.2
376
7 x 2 RE / 2
12.1
16
12
16.7
401
7 x 2 RE / 3
12.1
16
12
16.7
410
7 x 2 RE / 6
12.1
16
12
17.3
448
7 x 2 RE / 16
12.1
16
12
17.7
535
10 x 2 RE / 3
12.1
13
10
19.6
548
10 x 2 RE / 6
12.1
13
10
20.2
586
10 x 2 RE / 16
12.1
13
10
20.6
674
12 x 2 RE / 2
12.1
12
10
20.0
581
12 x 2 RE / 3
12.1
12
10
20.0
590
12 x 2 RE / 16
12.1
12
10
21.0
716
14 x 2 RE / 4
12.1
12
9
21.3
660
14 x 2 RE / 16
12.1
12
9
21.7
767
16 x 2 RE / 4
12.1
11
9
22.3
586
16 x 2 RE / 16
12.1
11
9
23.2
721
19 x 2 RE / 2
12.1
11
9
22.4
772
19 x 2 RE / 4
12.1
11
9
23.0
799
19 x 2 RE / 6
12.1
11
9
23.0
819
19 x 2 RE / 16
12.1
11
9
23.4
904
24 x 2 RE / 2
12.1
9
8
25.7
988
24 x 2 RE / 6
12.1
9
8
26.3
1036
24 x 2 RE / 16
12.1
9
8
26.7
1119
30 x 2 RE / 16
12.1
8
7
27.8
1250
37 x 2 RE / 6
12.1
8
7
29.1
1345
37 x 2 RE / 16
12.1
8
7
29.5
1426
44 x 2 RE / 16
12.1
7
6
32.4
1671
48 x 2 RE / 16
12.1
7
6
32.8
1746
61 x 2 RE / 16
12.1
7
6
33.5
1951
2 x 3 RE / 3
7.41
42
27
14.2
286
2 x 3 RE / 16
7.41
42
27
15.2
412
3 x 3 RE / 3
7.41
36
25
14.7
318
3 x 3 RE / 16
7.41
36
25
15.7
444
4 x 3 RE / 3
7.41
36
25
15.6
361
4 x 3 RE / 6
7.41
36
25
16.2
400
4 x 3 RE / 16
7.41
36
25
16.6
487
5 x 3 RE / 3
7.41
25
19
16.5
407
5 x 3 RE / 16
7.41
25
19
17.5
533
7 x 3 RE / 3
7.41
21
17
17.9
505
7 x 3 RE / 6
7.41
21
17
18.5
543
7 x 3 RE / 16
7.41
21
17
18.9
630
10 x 3 RE / 4
7.41
18
14
21.7
704
10 x 3 RE / 16
7.41
18
14
22.1
812
12 x 3 RE / 4
7.41
17
13
22.2
765
12 x 3 RE / 16
7.41
17
13
22.6
876
14 x 3 RE / 16
7.41
16
13
23.4
948
16 x 3 RE / 6
7.41
15
12
22.1
831
16 x 3 RE / 16
7.41
15
12
23.1
1101
19 x 3 RE / 6
7.41
14
11
25.3
1077
19 x 3 RE / 16
7.41
12
11
25.7
1160
24 x 3 RE / 6
7.41
12
10
28.6
1338
24 x 3 RE / 10
7.41
12
10
29.0
1369
24 x 3 RE / 16
7.41
12
10
29.0
1420
30 x 3 RE / 6
7.41
11
9
29.9
1527
30 x 3 RE / 16
7.41
11
9
30.3
1608
37 x 3 RE / 16
7.41
11
9
31.3
1971
48 x 3 RE / 16
7.41
9
8
34.5
2441
2 x 4 RE / 4
4.61
54
37
16.5
383
2 x 4 RE / 16
4.61
54
37
16.9
491
3 x 4 RE / 4
4.61
46
34
17.1
431
4 x 4 RE / 4
4.61
46
34
18.1
493
4 x 4 RE / 16
4.61
46
34
18.5
601
5 x 4 RE / 4
4.61
32
25
19.3
561
5 x 4 RE / 16
4.61
32
25
19.7
669
7 x 4 RE / 4
4.61
28
21
20.9
700
7 x 4 RE / 16
4.61
28
21
21.3
808
10 x 4 RE / 6
4.61
25
18
25.4
1019
14 x 4 RE / 16
4.61
24
17
27.5
1304
2 x 6 RE / 6
3.08
68
48
17.5
470
2 x 6 RE / 16
3.08
68
48
16.1
481
3 x 6 RE / 6
3.08
58
43
18.2
535
4 x 6 RE / 6
3.08
58
43
19.3
618
4 x 6 RE / 16
3.08
58
43
19.7
705
5 x 6 RE / 16
3.08
41
32
21.0
794
2 x 10 RE / 16
1.83
90
66
19.9
702
4 x 10 RE / 16
1.83
78
59
22.1
933
4 x 10 RM / 16
1.83
78
59
20.7
876
5 x 10 RM / 16
1.83
55
44
23.8
1021
2 x 16 RE / 10
1.15
116
89
19.6
806
3 x 16 RE / 10
1.15
101
78
21.1
941
4 x 16 RE / 10
1.15
101
78
24.7
1189
4 x 16 RE / 16
1.15
101
78
24.4
1141
5 x 16 RM / 16
1.15
71
59
26.1
1381
3 x 25 RM / 16
0.727
132
105
25.1
1421
4 x 25 RM / 16
0.727
132
105
28.2
1641

Technical changes reserved.

All figures are therefore without guarantee.

To inquiry

Check other recommended products by SKB Group

Earthing and Short Circuiting Cables and Bare Wires

Browse products
Earthing and Short Circuiting Cables and Bare Wires
Instalation and Harmonised Cables and Wires
Low Voltage Cables 0,6/1 kV
Safety Cables with circuit integrity
Medium Voltage Cables up to 36 kV
Rubber, Silicone and PUR Cables
Commercial Vehicles and EVC Cables
Automation and Motor Supply Cables
Railway Signalling and Telecommunications Cables
Special Cables

Our Code of Conduct and its associated regulations are not seeking to „invent“ new approaches. Instead, they aim to clearly demonstrate the obligations we must fulfill nowadays.

Let's work
together

SKW

Discover

SKB Group

SKW logo

SKW Schwechater Kabelwerke GmbH

Himberger Straße 50, 2320 Schwechat

  • +43 1 70170 0

  • [email protected]

  • Terms and Conditions

  • Impressum

  • Compliance

  • Privacy Policy

All rights reserved. Copyright © 2025