F-2YA2Y

Download PDF

Add to inquiry

Download PDF

To inquiry

Telecommunication underground cable, screened

Telecommunications cables

Underground cable for use in telecommunications installations and related installations. Suitable for installation under ground, in water, cable ducts etc.

Design

This product consists of:

  • 1
    Copper conductor, round solid (RE)
  • 2
    Core insulation (PE), cores star quaded and quads stranded in layers
  • 3
    Inner covering (plastic tape)
  • 4
    Screen (plastic laminated aluminium tape with drain wire)
  • 5
    Sheath (PE black, UV-resistant)

Technical Data

Standard: 
  • adapted to Telekom Austria-Standard X 5019
  • EN 50556
Test Voltage: 
  • 500 V (core/core) / 50 Hz
  • 2 kV (core/screen) / 50 Hz
Rated Voltage: max. 200 Veff
Bending radius (min.): 10 x Ø of cable
Fire properties: CPR classification: Fca
Core identification: Colour code with trace quad in each layer (TA standard)
Temperature range: 
  • Laying temperature: min. -20°C
  • Conductor temperature: max. 80°C
Cable image - F-2YA2Y
+
-
Cable image - F-2YA2Y
+
-
Cable image - F-2YA2Y
+
-

Contact us

Are you interested in this product?

Dogan Özcan, MSc

Product supervisor

+43 (0) 1 70170-154
[email protected]

Electricity

Add to inquiry
Parameter
Unit
Values
Conductor diameter (mm)
mm
0.6
0.8
Conductor resistance, max. at 20 °C (Ω/km)
Ω/km
130
73.2
Insulation resistance, min. at 20 °C (MΩ/km)
MΩ/km
10000
10000
Mutual capacitance (approx. value), at 800 Hz (nF/km)
nF/km
55
55

Options

Add to inquiry
Number of pairs x nominal diameter
Outer diameter appr. (mm)
Total weight appr. (kg/km)
Standard lengths/packing (m)
2 x 2 x 0.6
7.2
47
500 T, 1000 T
6 x 2 x 0.6
9.3
85
500 T, 1000 T
10 x 2 x 0.6
10.5
118
500 T, 1000 T
20 x 2 x 0.6
14.5
207
500 T, 1000 T
30 x 2 x 0.6
15.3
274
500 T, 1000 T
40 x 2 x 0.6
16.6
345
500 T, 1000 T
50 x 2 x 0.6
18.0
417
500 T, 1000 T
60 x 2 x 0.6
19.4
489
500 T, 1000 T
100 x 2 x 0.6
25.5
792
500 T, 1000 T
2 x 2 x 0.8
7.9
60
500 T, 1000 T
4 x 2 x 0.8
11.0
103
500 T, 1000 T
6 x 2 x 0.8
10.6
121
500 T, 1000 T
10 x 2 x 0.8
12.1
175
500 T, 1000 T
20 x 2 x 0.8
17.2
317
500 T, 1000 T
30 x 2 x 0.8
18.1
432
500 T, 1000 T
40 x 2 x 0.8
19.8
552
500 T, 1000 T
50 x 2 x 0.8
21.5
672
500 T, 1000 T
60 x 2 x 0.8
23.5
797
500 T, 1000 T
100 x 2 x 0.8
31.1
1303
500 T, 1000 T

Technical changes reserved.

All figures are therefore without guarantee.

To inquiry

Check other recommended products by SKB Group

Telecommunications cables

Browse products
Telecommunications cables
Control and Electronic Cables
Conductors
Fire Alarm Cables
Halogen-free Cables and Wires
Halogen-free Control and Electronic Cables
Halogen-free Power Cables
Halogen-free Telecommunication Cables
Industrial Cables
Railway Signalling Cables
Solar Cables
Telecommunication Cables
PVC and Rubber Cables and Wires
Control and electronics cables
Power Cables and Overhead Lines 0.6/1 kV
Safety Cables
Medium Voltage Cables 10 - 30 kV
Silicone, PUR and Building Site Cables

Our Code of Conduct and its associated regulations are not seeking to „invent“ new approaches. Instead, they aim to clearly demonstrate the obligations we must fulfill nowadays.

Let's work
together

SKW

SKB Group

SKW

SKW Schwechater Kabelwerke GmbH

Himberger Straße 50, 2320 Schwechat

  • +43 1 70170 0

  • [email protected]

Follow us:

  • Terms and Conditions

  • Impressum

  • Compliance

  • Privacy Policy

  • Whistleblowing

All rights reserved. Copyright © 2026