SKW
SKB
PRAKAB
ICS
KONEKA
IKK

Menu

Certificate

EcoVadis Rated: Bronze Medal

Join SCHWECHATER KABELWERKE GMBH on its sustainability journey! Our EcoVadis assessment has earned us a Bronze Medal, an award given to the top 35% of companies evaluated worldwide.

Certificate
  • Drum return
  • DOP Finder
  • Download Center
  • Compliance
  • Whistleblowing
  • Videos
  • Stock Level
SKW logo
Cu
SKW
Date: 05.12.2025
Cu
Quotation€ / 100 kg:1,043.92
Surcharge€ / 100 kg:913.92
SKB-Group
Date: 05.12.2025
Cu
Quotation
€ / 100 kg:1,031.57

All statements without guarantee.

Al
SKW
Date: 05.12.2025
Al
Quotation€ / 100 kg:408.03
Surcharge€ / 100 kg:308.03
SKB-Group
Date: 05.12.2025
Al
Quotation
€ / 100 kg:360.92

All statements without guarantee.

Cables

H07RN-F (GMSuö)

Download PDF

Add to inquiry

Download PDF

To inquiry

Heavy flexible cable, oil resistant

Usable under medium to heavy mechanical stress in dry and wet rooms, in in free ambient or rooms subject to explosion hazards. Permissible for fixed installation on hoisting equipments, machinery etc. and for rated voltages up to 1000 V if installed protected in tubes or inside of devices and as motor power supply cable.

Design

This product consists of:

  • 1
    Kupferleiter, feindrähtig (–F)
  • 2
    Aderisolation (EPR-Gummi)
  • 3
    Mantel (Chloropren-Gummi schwarz, ölbeständig und abriebfest)

Technical Data

Standard: EN 50525-2-21
Certificate: VDE Germany
Test Voltage: 2.5 kV / 50 Hz
Rated Voltage: 450/750 V (Uo/U)
Bending radius (min.): 4 x Ø of cable
Fire properties: EN 60332-1-2: flame retardant
Core identification: HD 308 S2
Temperature range: 
  • Laying temperature: min. -25°C
  • Operating temperature: -25°C up to 50°C
  • Conductor temperature: max. 60°C
  • Short circuit temperature: max. 200°C
Cable image - H07RN-F (GMSuö)
+
-
Cable image - H07RN-F (GMSuö)
+
-
Cable image - H07RN-F (GMSuö)
+
-

Contact us

Are you interested in this product?

Dogan Özcan

Product supervisor

+43 (0) 1 70170-154
[email protected]

Options

Add to inquiry
Number of cores x nominal cross-section
Max. conductor resistance (Ω/km)
Outer diameter appr. (mm)
Total weight appr. (kg/km)
Standard lengths/packing (m)
2 x 1
20.0
9.0
100
500 Sp, 1000 Sp
3 x 1
20.0
9.5
120
500 Sp, 1000 Sp
4 x 1
20.0
11.5
190
500 Sp, 1000 Sp
5 x 1
20.0
11.5
180
500 Sp, 1000 Sp
2 x 2
13.7
9.5
130
500 Sp, 1000 Sp
3 x 2
13.7
10.5
150
100 R, 500 Sp, 1000 T
3 x 2
13.7
10.5
150
100 R, 500 Sp, 1000 T
4 x 2
13.7
11.5
190
100 R, 500 Sp, 1000 T
5 x 2
13.7
12.5
230
100 R, 500 Sp, 1000 T
5 x 2
13.7
12.5
230
500 T, 1000 T
7 x 2
13.7
15.5
330
500 T, 1000 T
9 x 2
13.7
17.0
428
500 T, 1000 T
12 x 2
13.7
20.0
470
500 T, 1000 T
19 x 2
13.7
23.0
620
500 T, 1000 T
24 x 2
13.7
25.5
1000
500 T, 1000 T
27 x 2
13.7
27.0
1077
500 T, 1000 T
37 x 2
13.7
33.0
1290
500 T, 1000 T
2 x 3
8.21
11.5
190
500 Sp, 1000 Sp
3 x 3
8.21
12.5
220
100 R, 500 Sp, 1000 T
3 x 3
8.21
12.5
220
100 R, 500 Sp, 1000 T
4 x 3
8.21
14.0
280
100 R, 500 Sp, 1000 T
5 x 3
8.21
15.5
340
100 R, 500 Sp, 1000 T
5 x 3
8.21
15.5
340
500 T, 1000 T
7 x 3
8.21
17.5
470
500 T, 1000 T
12 x 3
8.21
23.0
650
500 T, 1000 T
19 x 3
8.21
28.0
1100
500 T, 1000 T
24 x 3
8.21
32.5
1260
500 T, 1000 T
27 x 3
8.21
36.0
1577
500 T, 1000 T
1 x 4
5.09
8.0
105
500 T, 1000 T
2 x 4
5.09
13.5
240
500 T, 1000 T
3 x 4
5.09
14.5
305
500 T, 1000 T
4 x 4
5.09
16.0
390
500 T, 1000 T
5 x 4
5.09
17.5
470
500 T, 1000 T
5 x 4
5.09
17.5
470
500 T, 1000 T
7 x 4
5.09
20.0
703
500 T, 1000 T
12 x 4
5.09
26.5
1020
500 T, 1000 T
1 x 6
3.39
9.0
140
500 T, 1000 T
2 x 6
3.39
15.0
290
500 T, 1000 T
3 x 6
3.39
16.0
495
500 T, 1000 T
3 x 6
3.39
16.0
495
500 T, 1000 T
4 x 6
3.39
17.5
520
500 T, 1000 T
5 x 6
3.39
19.0
640
500 T, 1000 T
5 x 6
3.39
19.0
640
500 T, 1000 T
1 x 10
1.95
11.0
210
500 T, 1000 T
2 x 10
1.95
21.0
620
500 T, 1000 T
3 x 10
1.95
22.0
880
500 T, 1000 T
4 x 10
1.95
24.0
950
500 T, 1000 T
5 x 10
1.95
26.0
1150
500 T, 1000 T
1 x 16
1.24
12.0
290
500 T, 1000 T
3 x 16
1.21
24.5
1260
500 T, 1000 T
4 x 16
1.24
27.0
1400
500 T, 1000 T
5 x 16
1.24
30.0
1700
500 T, 1000 T
1 x 25
0.795
13.5
410
500 T, 1000 T
3 x 25
0.795
28.5
1457
500 T, 1000 T
4 x 25
0.795
32.5
1950
500 T, 1000 T
5 x 25
0.795
36.0
2400
500 T, 1000 T
1 x 35
0.565
16.0
560
500 T, 1000 T
3 x 35
0.565
29.6
1850
500 T, 1000 T
4 x 35
0.565
37.0
2700
500 T, 1000 T
5 x 35
0.565
38.0
3000
500 D
1 x 50
0.393
17.6
740
500 T, 1000 T
1 x 50
0.393
17.6
740
500 T, 1000 T
3 x 50
0.393
36.0
3790
500 D
4 x 50
0.393
42.0
3600
500 D
5 x 50
0.393
44.5
3950
500 D
1 x 70
0.277
21.0
1050
500 T, 1000 T
4 x 70
0.277
49.5
4900
500 D
1 x 95
0.21
23.0
1300
500 T, 1000 T
4 x 95
0.21
55.5
6200
500 D
1 x 120
0.164
25.0
1560
500 T, 1000 T
4 x 120
0.164
60.0
7800
500 D
1 x 150
0.132
28.0
2000
500 T, 1000 T
4 x 150
0.132
65.0
9700
500 D
5 x 150
0.132
73.0
10500
500 D
1 x 185
0.108
31.0
2300
500 T, 1000 T
4 x 185
0.108
65.0
9700
500 D
1 x 240
0.082
34.0
3000
500 T, 1000 T
4 x 240
0.082
74.0
13120
500 D
1 x 300
0.064
34.1
3600
500 T, 1000 T

Technical changes reserved.

All figures are therefore without guarantee.

To inquiry

Check other recommended products by SKB Group

Earthing and Short Circuiting Cables and Bare Wires

Browse products
Earthing and Short Circuiting Cables and Bare Wires
Instalation and Harmonised Cables and Wires
Low Voltage Cables 0,6/1 kV
Safety Cables with circuit integrity
Medium Voltage Cables up to 36 kV
Rubber, Silicone and PUR Cables
Commercial Vehicles and EVC Cables
Automation and Motor Supply Cables
Railway Signalling and Telecommunications Cables
Special Cables

Our Code of Conduct and its associated regulations are not seeking to „invent“ new approaches. Instead, they aim to clearly demonstrate the obligations we must fulfill nowadays.

Let's work
together

SKW

Discover

SKB Group

SKW logo

SKW Schwechater Kabelwerke GmbH

Himberger Straße 50, 2320 Schwechat

  • +43 1 70170 0

  • [email protected]

  • Terms and Conditions

  • Impressum

  • Compliance

  • Privacy Policy

All rights reserved. Copyright © 2025