Cables

LiYCY

Download PDF

Add to inquiry

Download PDF

To inquiry

Electronic control cable, screened

Control and electronics cables

In Meß-, Steuer- und Regelgeräten im Bereich der Elektronik zur Übertragung von Signalen im Milliamperebereich, zum Schutz vor Neben- bzw. Übersprechen der Leitungskreise untereinander, sowie vor elektrischen Fremdeinflüssen.

Design

This product consists of:

  • 1
    Kupferleiter, feindrähtig
  • 2
    Aderisolation (PVC), Adern in Lagen verseilt
  • 3
    Bebänderung (Kunststofffolie)
  • 4
    Schirm (Geflechtschirm aus verzinnten Kupferdrähten)
  • 5
    Mantel (PVC grau RAL 7001)

Technical Data

Standard: adapted to DIN VDE 0812
Test Voltage: 800 Veff (0,14 mm) / 50 Hz 1200 Veff (≥ 0,25 mm) / 50 Hz
Rated Voltage: max. 350 Vss (0,14 mm) max. 500 Vss (≥ 0,25 mm)
Bending radius (min.): 4 x Ø der Leitung
Fire properties: EN 60332-1-2: selbstverlöschend CPR-Klassifizierung: Eca
Core identification: DIN 47100
Temperature range: 
  • Laying temperature: min. -5°C
  • Conductor temperature: max. 70°C
  • Fixed installation: -30°C up to 70°C
  • Flexible use: -5°C up to 70°C
Cable image - LiYCY
+
-
Cable image - LiYCY
+
-
Cable image - LiYCY
+
-

Contact us

Are you interested in this product?

Dogan Özcan

Product supervisor

+43 (0) 1 70170-154
[email protected]

Electricity

Add to inquiry
Parameter
Unit
Values
Conductor diameter (mm)
mm
0.14
0.25
0.34
0.5
0.75
1
1.5
Conductor resistance, max. at 20 °C (Ω/km)
Ω/km
148
79.9
75.4
39
26
19.5
13.3
Insulation resistance, min. at 20 °C (MΩ/km)
MΩ/km
200
200
200
200
200
200
200
Mutual capacitance (approx. value), at 800 Hz (nF/km)
nF/km
120
120
120
150
150
150
150

Options

Add to inquiry
Number of cores x conductor diameter
Outer diameter appr. (mm)
Total weight appr. (kg/km)
Standard lengths/packing (m)
2 x 0.14
3.5
20
1000 Sp
3 x 0.14
4
40
1000 Sp
4 x 0.14
4.1
43
1000 Sp
5 x 0.14
4.8
47
1000 Sp
6 x 0.14
4.9
52
1000 Sp
7 x 0.14
5
54
1000 Sp
8 x 0.14
5.3
58
1000 Sp
10 x 0.14
6.4
76
1000 Sp
12 x 0.14
6.7
81
1000 Sp
14 x 0.14
6.9
89
1000 Sp
16 x 0.14
7.3
97
1000 Sp
20 x 0.14
7.8
116
1000 Sp
24 x 0.14
9.1
158
1000 Sp
25 x 0.14
9.2
165
1000 Sp
32 x 0.14
10
198
1000 Sp
36 x 0.14
10.2
231
1000 Sp
40 x 0.14
10.5
252
1000 Sp
50 x 0.14
12
327
1000 Sp
2 x 0.25
3.9
28
1000 Sp
3 x 0.25
4.3
34
1000 Sp
4 x 0.25
4.5
40
1000 Sp
5 x 0.25
5.1
47
1000 Sp
6 x 0.25
5.5
54
1000 Sp
7 x 0.25
5.9
61
1000 Sp
8 x 0.25
5.9
66
1000 Sp
10 x 0.25
6.4
80
1000 Sp
12 x 0.25
6.5
91
1000 Sp
14 x 0.25
8
120
1000 Sp
16 x 0.25
9.6
135
1000 Sp
18 x 0.25
10
150
1000 Sp
20 x 0.25
10.2
157
1000 Sp
24 x 0.25
12.1
212
1000 Sp
25 x 0.25
12.1
220
1000 Sp
32 x 0.25
13
256
1000 Sp
40 x 0.25
14.1
302
1000 Sp
50 x 0.25
16
461
1000 Sp
2 x 0.34
4.6
31
1000 Sp
3 x 0.34
4.7
31
1000 Sp
4 x 0.34
5.2
46
1000 Sp
5 x 0.34
5.6
54
1000 Sp
6 x 0.34
5.8
62
1000 Sp
7 x 0.34
5.9
70
1000 Sp
8 x 0.34
6.2
76
1000 Sp
10 x 0.34
6.9
114
1000 Sp
12 x 0.34
7.2
128
1000 Sp
14 x 0.34
9.5
141
1000 Sp
16 x 0.34
10
155
1000 Sp
18 x 0.34
10.7
186
1000 Sp
20 x 0.34
10.9
195
1000 Sp
24 x 0.34
13
244
1000 Sp
36 x 0.34
14.3
325
1000 Sp
2 x 0.5
5
36
1000 Sp
3 x 0.5
5.4
45
1000 Sp
4 x 0.5
5.9
54
1000 Sp
5 x 0.5
6.6
67
1000 Sp
6 x 0.5
7.1
76
1000 Sp
7 x 0.5
7.2
84
1000 Sp
8 x 0.5
7.6
107
1000 Sp
10 x 0.5
8.8
134
1000 Sp
12 x 0.5
8.9
155
1000 Sp
16 x 0.5
10.7
186
1000 Sp
18 x 0.5
11
217
1000 Sp
20 x 0.5
11.6
239
1000 Sp
24 x 0.5
13.3
300
1000 Sp
2 x 0.75
5.6
6.2
1000 Sp
3 x 0.75
6
73
1000 Sp
4 x 0.75
6.6
92
1000 Sp
5 x 0.75
7
110
1000 Sp
6 x 0.75
7.7
128
1000 Sp
7 x 0.75
7.8
145
1000 Sp
8 x 0.75
9.4
151
1000 Sp
10 x 0.75
9.8
182
1000 Sp
12 x 0.75
9.9
216
1000 Sp
2 x 1
6
74
1000 Sp
3 x 1
6.4
89
1000 Sp
4 x 1
6.9
107
1000 Sp
5 x 1
7.5
132
1000 Sp
6 x 1
8.3
158
1000 Sp
7 x 1
10.4
254
1000 Sp
2 x 1.5
6.6
86
1000 Sp
3 x 1.5
7
107
1000 Sp
4 x 1.5
7.9
129
1000 Sp
5 x 1.5
8.9
150
1000 Sp
2 x 2.5
8.5
140
1000 Sp

Technical changes reserved.

All figures are therefore without guarantee.

To inquiry

Check other recommended products by SKB Group

Earthing and Short Circuiting Cables and Bare Wires

Browse products
Earthing and Short Circuiting Cables and Bare Wires
Instalation and Harmonised Cables and Wires
Low Voltage Cables 0,6/1 kV
Safety Cables with circuit integrity
Medium Voltage Cables up to 36 kV
Rubber, Silicone and PUR Cables
Commercial Vehicles and EVC Cables
Automation and Motor Supply Cables
Railway Signalling and Telecommunications Cables
Special Cables

Our Code of Conduct and its associated regulations are not seeking to „invent“ new approaches. Instead, they aim to clearly demonstrate the obligations we must fulfill nowadays.

Let's work
together

SKW

Discover

SKB Group

SKW logo

SKW Schwechater Kabelwerke GmbH

Himberger Straße 50, 2320 Schwechat

  • +43 1 70170 0

  • [email protected]

  • Terms and Conditions

  • Impressum

  • Compliance

  • Privacy Policy

All rights reserved. Copyright © 2025